Comparison of Cranial Ultrasound and Amplitude-Integrated Electroencephalography in Predicting Neurodevelopmental Outcomes in Neonates With Hypoxic-Ischemic Encephalopathy: A Systematic Review and Meta-Analysis.

J Clin UltrasoundJul 17, 2026 (epub)

Meirong Shu, Shilue Zhong, Bo Bao et al.

✦ AI-curated · Sources linked

In 30 seconds

This systematic review and meta-analysis assessed how amplitude-integrated electroencephalography (aEEG) and cranial ultrasound (cUS) predict neurodevelopmental outcomes in term and near-term neonates with hypoxic-ischaemic encephalopathy. Ten observational studies included 901 neonates. The pooled proportion with an adverse neurodevelopmental outcome was 0.44 (95% CI: 0.34-0.54; I 2 = 84.0%). For aEEG, the pooled diagnostic odds ratio for predicting an adverse outcome was 18.85 (95% CI: 7.31-48.65). Adverse outcome proportions were similar across aEEG, cUS, and conventional EEG-based patterns, with no significant between-group differences.

Key findings

  • Across 10 studies and 901 neonates, the pooled proportion with adverse neurodevelopmental outcomes was 0.44 (95% CI: 0.34-0.54; I 2 = 84.0%).
  • For aEEG, the pooled diagnostic odds ratio for adverse neurodevelopmental outcomes was 18.85 (95% CI: 7.31-48.65).
  • Adverse outcome proportions were 0.43 for aEEG, 0.42 for cUS, and 0.50 for conventional EEG-based patterns, with no significant between-group differences.
  • The pooled incidence of cerebral palsy was 0.02 (95% CI: 0.01-0.07), with low to moderate heterogeneity.

Why it matters

Neurodevelopmental impairment remains common among neonates with HIE, and early prognostic information can help frame follow-up and outcome assessment. These pooled findings suggest aEEG has prognostic value, while cUS may contribute complementary information. The substantial heterogeneity in adverse outcomes also underscores the difficulty of comparing prognostic performance across studies.

What to keep in mind

The review included observational studies, and adverse-outcome estimates showed substantial heterogeneity (I 2 = 84.0%).

Source

Published in J Clin Ultrasound. This summary was written by xxcode from the publication's abstract and metadata. It is not peer reviewed and is not a substitute for the original article. For clinical decisions, review the original publication.

ShareTelegramLinkedIn

AI-generated summaries may contain errors or omissions. Verify clinically important information with the original publication.

More in Pediatrics

Want this personalized?

Stop searching the literature. Choose what you follow and xxcode will build your personalized medical digest.

  • Your specialties
  • Your filters and thresholds
  • Clinical Research + Case Reports, tuned separately
  • Automatic weekly delivery
  • Audio and text

Prefer listening? Personalized audio digests are available with Pro.

Stay updated for free

Get the 3 most interesting publications in one specialty each week.

Weekly email. Unsubscribe anytime.