A randomised controlled crossover trial comparing two mandibular repositioning appliances for treatment of moderate obstructive sleep apnoea.

Sleep BreathOct 28, 2026 (epub)
Clinical ResearchPulmonologyOtolaryngology (ENT)Open access

Jorden Blok, Zoë Van Houtvinck, Susie Klerkx et al.

✦ AI-curated · Sources linked

In 30 seconds

This single-centre, randomised two-period crossover trial compared two custom-made mandibular repositioning appliances in 16 adults with moderate obstructive sleep apnoea. Each appliance was worn for three months, separated by a two-week washout. Median AHI decreased from 17.6 events/h at baseline to 3.1 with SomnoDent Flex and 2.3 with NOA (both p < 0.001 versus baseline). The non-prespecified comparison found a between-appliance difference of + 0.16 events/h (95% CI - 2.56 to + 2.87; p = 0.904), which does not establish equivalence.

Key findings

  • Median AHI fell from 17.6 events/h at baseline to 3.1 with SomnoDent Flex and 2.3 with NOA; both reductions had p < 0.001 versus baseline.
  • The between-appliance difference was + 0.16 events/h (95% CI - 2.56 to + 2.87; p = 0.904); the analysis did not establish equivalence.
  • A period effect of + 3.82 events/h occurred in period 2, when measurement changed from home polygraphy to in-laboratory polysomnography (p = 0.009).
  • Post hoc, AHI < 5 events/h was reached in 12/16 participants with SomnoDent Flex and 10/16 with NOA.

Why it matters

Both appliances were associated with substantial reductions in AHI in this small trial, suggesting that either may reduce measured disease severity in adults with moderate OSA. However, the comparison cannot show that the appliances perform equivalently. The period effect and change in measurement method also complicate interpretation, so the findings offer limited certainty about their comparative merits.

What to keep in mind

The trial included only 16 participants at one centre. Measurement method changed between periods, completely confounding period with methodology. Adherence, titration and adverse events were insufficiently assessed; adverse events were not systematically recorded.

Source

Published in Sleep Breath. This summary was written by xxcode from the publication's abstract and metadata. It is not peer reviewed and is not a substitute for the original article. For clinical decisions, review the original publication.

ShareTelegramLinkedIn

AI-generated summaries may contain errors or omissions. Verify clinically important information with the original publication.

More in Pulmonology

Want this personalized?

Stop searching the literature. Choose what you follow and xxcode will build your personalized medical digest.

  • Your specialties
  • Your filters and thresholds
  • Clinical Research + Case Reports, tuned separately
  • Automatic weekly delivery
  • Audio and text

Prefer listening? Personalized audio digests are available with Pro.

Stay updated for free

Get the 3 most interesting publications in one specialty each week.

Weekly email. Unsubscribe anytime.