First-in-human dosimetry and biodistribution of [ 89 Zr]Zr-oxine-labeled autologous leukocytes using PET/CT.

Eur J Nucl Med Mol ImagingOct 2, 2026 (epub)
Clinical ResearchNuclear MedicineRadiology (Diagnostic)Open access

Kadir Gultekin, Jennifer L Bartels, Carlos E Cardenas et al.

✦ AI-curated · Sources linked

In 30 seconds

This prospective first-in-human clinical trial evaluated the safety, biodistribution and radiation dosimetry of [89Zr]Zr-oxine-labeled autologous leukocytes in four healthy adult women. Participants received labeled cells and underwent serial whole-body PET/CT imaging over 72 hours. Administration was well tolerated, and imaging visualized leukocyte distribution and its temporal dynamics. The mean effective-dose coefficient was 0.92 ± 0.06 mSv/MBq, numerically below the predicted 1.14 mSv/MBq for [111In]In-oxine-labeled leukocytes in adult females (P = 0.006). The authors conclude that the approach has favorable dosimetry and supports further clinical and research evaluation.

Key findings

  • Administration was well tolerated in all four healthy female participants.
  • The mean effective-dose coefficient was 0.92 ± 0.06 mSv/MBq, versus a predicted 1.14 mSv/MBq for [111In]In-oxine-labeled leukocytes (P = 0.006).
  • The highest mean absorbed-dose coefficients were in the spleen (3.52 ± 1.38 mGy/MBq) and liver (2.1 ± 0.45 mGy/MBq).
  • PET/CT visualized leukocyte distribution and temporal dynamics.

Why it matters

PET tracking of labeled leukocytes could support imaging of infection and inflammation and monitoring of cell-based therapies. These initial human data provide estimates of radiation exposure and show that leukocyte distribution can be followed over time with [89Zr]Zr-oxine PET/CT, informing further evaluation of this imaging approach.

What to keep in mind

The study included only four healthy female participants, limiting the generalizability of its safety and dosimetry estimates to patients and other populations.

Source

Published in Eur J Nucl Med Mol Imaging. This summary was written by xxcode from the publication's abstract and metadata. It is not peer reviewed and is not a substitute for the original article. For clinical decisions, review the original publication.

ShareTelegramLinkedIn

AI-generated summaries may contain errors or omissions. Verify clinically important information with the original publication.

More in Nuclear Medicine

Want this personalized?

Stop searching the literature. Choose what you follow and xxcode will build your personalized medical digest.

  • Your specialties
  • Your filters and thresholds
  • Clinical Research + Case Reports, tuned separately
  • Automatic weekly delivery
  • Audio and text

Prefer listening? Personalized audio digests are available with Pro.

Stay updated for free

Get the 3 most interesting publications in one specialty each week.

Weekly email. Unsubscribe anytime.